- Testing Equipment[3]
- Fuse Components[2]
- Sander[4]
- Hand Carts & Trolleys[4]
- Gas Analyzers[7]
- Car Lifts[8]
- Other Vehicle Equipment[10]
- Diagnostic Tools[10]
- Cleaner & Wash[1]
- Tire Changers[7]
- Wheel Alignment[10]
- Other Car Cleaning Tools[7]
- Other Vehicle Tools[10]
- Other Car Care Equipment[9]
- Spray Booths[5]
- Other Car Care Products[1]
- Body Repair Equipment[4]
- Other Auto Parts[1]
- Contact Person : Ms. Chan Winnie
- Company Name : Guangzhou Shinai Machinery Equipment Co., Ltd.
- Tel : 86-020-86578659
- Fax : 86-020-86566830
- Address : Guangdong,Guangzhou,B38 show room,new century auto business centre,No.206 Guangyuan Middle RD,Guangzhou City,Guangdong Province,CHINA
- Country/Region : China
- Zip : 510000
Car Emission Analyzer
Detailed Product Description
Main Features and Specifications:
1.Measure concentration of HC, CO, CO2 Ocontained in exhaust gases from gasoline engine of
vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2 .
2.Designed with LCD screen for easier setting and operation.
3.Automatic calculation and display of A/F (air-fuel-ratio) and Lambda air ratio .
4.Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.
4.Small Size, light weight and most convenient for carry.
5.Designed with inductive clip-on pickup sensor for RPM measurement.
6.Designed with oil temperature measurement probe.
7.Designed with RS-232C digital serial interface.
8.200 groups of measurement data storage and review.
9.In compliance with accuracy requirement of ISO 3930 or OIML R99 Class .and 2
10Options and Accessories:
1)Micro printer.
2)Various RPM measurement adaptors.
3)DC12V vehicle power inverter.
4)Automotive Emission Analyzer
(4-gas / portable)
Main Technical Specifications:
1.easuring Range:
HC: 09,999 ppm (n-Hexane)
CO: 010 %
CO : 018 % 2
O : 025 % 2
2 Measurement Accuracy:
HC: ±12 ppm (abs.) 02,000 ppm
±5 % ( rel. ) 02,000 ppm (which ever is larger)
±10 % ( rel. ) 2,0019,999 ppm
CO: ±0.06 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO : ±0.5 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
O : ±0.1 % (abs.) 2
±5 % ( rel. ) (which ever is larger)
3.Response Time: Less than 10s for T90
(O , less than 12s) 2
4.Warm-up Time: 10 min.
(ambient temperature is not lower than 20)
5.Power Supply: AC220V ±10% 50Hz ±1Hz
6.Net Weight: 6.0Kg
7.Outer Dimension:
260mm(W) × 180mm(H) × 450mm(D)